The Silver Line series follows the industry accepted footprint for open frame, linear power supplies. Sola improves on this design by offering standard screw terminal connections and optional covers for safety considerations.
Features |
Applications |
Specifications |
Parameter | Condition | Limit |
Input | ||
Input Voltage | x | 100/120/220/230/240 VAC Selectable |
Input Frequency | x | 47-63 Hz |
Output | ||
Line Regulation | for 10% change | 0.05% |
Load Regulation | for 50% change | 0.05% |
Ripple | x | 3.0 mV maximum Peak-to-Peak |
DC Output Adjustment Range | x | ±5% Minimum |
Overvoltage Protection | x | All 5-Volt outputs include build-in OVP as standard (setting is 6.2 V ±0.4 V) OVP is optionally available on other types |
Transient Response Time | at 50% Load Changes | 50 msec. |
Overload Protection | Automatic current limit foldback | |
Remote Sensing | Available to compensate for output voltage drop on selected models | 0.5 VDC |
General | ||
Operating Temperature Range | Derate to 40% at +70°C | 0 to +50°C |
Storage Temperature Range | -25°C to +85°C | |
Temperature Coefficient (Typical) | 0.01%°C | |
Stability | After warm-up | ± 0.5% |
Vibration | Method 514 | Per MIL-STD-810C |
Shock | Method 516 | Per MIL-STD-810C |
EMI/RFI | Linear power supplies have inherently low conducted and radiate noise levels | For most system applications they will meet requirements of FCC Class B and VDE 0871 for Class B |
Cover Option | Derate power by an additional 15% | |
Cooling | Forced air. | |
*Specifications are typical. Load Regulation on outputs without Remote Sense, 0.1% typical. |
Selection |
Catalog Number | OUTPUT 1 | OUTPUT 2 | OUTPUT 3 |
SLS-05-030-1T | 5 V @ 3 A*# | - | - |
SLS-05-060-1T | 5 V @ 6 A*# | - | - |
SLS-05-090-1T | 5 V @ 9 A*# | - | - |
SLS-05-120-1T | 5 V @ 12 A*# | - | - |
SLS12-017T1 | 12 V @ 1.7 A# or 15 V @ 1.5 | - | - |
SLS-12-034T | 12 V @ 3.4 A# | - | - |
SLS-12-051T | 12 V @ 5.1 A# | - | - |
SLS-12-068T | 12 V @ 6.8 A# | - | - |
SLS-15-045T | 15 V @ 4.5 A# | - | - |
SLS-15-060T | 15 V @ 6 A# | - | - |
SLS-24-012T | 24 V @ 1.2 A# | - | - |
SLS-24-024T | 24 V @ 2.4 A# | - | - |
SLS-24-036T | 24 V @ 3.6 A# | - | - |
SLS-24-048T | 24 V @ 4.8 A# | - | - |
SLS-24-072T | 24 V @ 7.2 A# | - | - |
SLS-24-120T | 24 V @ 12.0 A# | - | - |
SLD12-1010-12T1 | 12 V @ 1 A or 15 V @ .8 A | -12 V @ 1 A or -15 V @ .8 | - |
SLD12-1818-12T1 | 12 V @ 1.8 A or 15 V @ 1.5 A | -12 V @ 1.8 A or -15 V @ 1.5 A | - |
SLD-12-3434-12T | 12 V @ 3.4 A# | -12 V @ 3.4 A# | - |
SLD-15-3030-15T | 15 V @ 3 A# | -15 V @ 3 A# | - |
SLD-12-6034-05T | 5 V @ 6 A*# | 12 V @ 3.4 A# | - |
SLD-12-3015-05T | 5 V @ 3 A*# | 12 V@ 1.5 A | - |
SLT12-20404-12T1 | 5 V @ 2 A*# | 12 V @ .4 A or 15 V @ .4 A | -12 V @ .4 A or -15 V @ .4 A |
SLT12-31010-12T1 | 5 V @ 3 A*# | 12 V @ 1 A# or 15 V @ .8 A | -12 V @ 1 A# or -15 V @ .8 A |
SLT12-61010-12T1 | 5V @ 6 A*# | 12 V @ 1 A or 15 V @ 1 A | -12 V @ 1 A or -15 V @ 1 A |
SLT12-61818-12T1 | 5V @ 6A*# | 12 V @1.8 A or 15 V @1.5 A | -12 V @ 1.8 A or -15 V @ 1.5 A |
SLT24-30530-05T1 | 5V @ 3A* | -5 V @ .5 A* | 24 V @ 3 A* |
Over Voltage Protector (OVP) | |||
SLO-12-000-1 | 6.2 V to 34 V | For Cases B through K | |
SLO-12-000-TB | 6.2 V to 34 V | For Case A or Cases B through K (when used with a cover) |