  • Manufacturer:: SolaHD
Product Code: SLS12034T
UPC Code: 78347260052
Silver Line Series - Single & Multi-Output Linears

The Silver Line series follows the industry accepted footprint for open frame, linear power supplies. Sola improves on this design by offering standard screw terminal connections and optional covers for safety considerations.

Features
  • Easy-to-install screw terminal connections
  • Cover options
  • Industry standard footprint
  • Universal input and approvals (115/230 VAC)
  • Low noise, extremely quiet DC output for noise sensitive or analog circuitry
  • Fast transient response. Ideal for test applications.
  • Built-in OVP on 5 V models and optional on 12, 15 and 24 V models
  • Automatic resetting overload protection
  • Short circuit protected
  • Two year warranty
Applications
  • Industrial control circuits and components
  • Instrumentation
  • Drives
  • CNC machinery
  • Equipment for food industry
  • Microprocessor circuits
  • Analog circuits
  • Noise sensitive circuitry and sensors
Specifications

ParameterConditionLimit

Input

Input Voltagex 100/120/220/230/240
VAC Selectable
Input Frequencyx 47-63 Hz

Output

Line Regulation for 10% change 0.05%
Load Regulation for 50% change 0.05%
Ripplex 3.0 mV maximum
Peak-to-Peak
DC Output
Adjustment Range
x ±5% Minimum
Overvoltage Protectionx
All 5-Volt outputs include
build-in OVP as standard
(setting is 6.2 V ±0.4 V)
OVP is optionally available
on other types
Transient Response Time at 50% Load Changes 50 msec.
Overload Protection Automatic current
limit foldback
Remote Sensing
Available to compensate
for output voltage drop
on selected models

0.5 VDC

General

Operating Temperature
Range

Derate to 40% at +70°C

0 to +50°C
Storage Temperature Range
-25°C to +85°C
Temperature
Coefficient (Typical)
0.01%°C
StabilityAfter warm-up ± 0.5%
VibrationMethod 514 Per MIL-STD-810C
ShockMethod 516 Per MIL-STD-810C
EMI/RFI
Linear power supplies have
inherently low conducted
and radiate noise levels
For most system applications
they will meet requirements
of FCC Class B and VDE 0871
for Class B
Cover Option

Derate power by an additional 15%

Cooling

Forced air.
20 CFM required for full rating
Derate 30% without cooling.

*Specifications are typical. Load Regulation on outputs without Remote Sense, 0.1% typical.


Selection

Catalog
Number
OUTPUT 1OUTPUT 2OUTPUT 3
SLS-05-030-1T 5 V @ 3 A*#--
SLS-05-060-1T 5 V @ 6 A*#--
SLS-05-090-1T 5 V @ 9 A*#--
SLS-05-120-1T 5 V @ 12 A*#--
SLS12-017T1 12 V @ 1.7 A#
or 15 V @ 1.5
--
SLS-12-034T 12 V @ 3.4 A#--
SLS-12-051T 12 V @ 5.1 A#--
SLS-12-068T12 V @ 6.8 A#--
SLS-15-045T 15 V @ 4.5 A#--
SLS-15-060T15 V @ 6 A#--
SLS-24-012T24 V @ 1.2 A#--
SLS-24-024T 24 V @ 2.4 A#--
SLS-24-036T24 V @ 3.6 A#--
SLS-24-048T24 V @ 4.8 A# --
SLS-24-072T24 V @ 7.2 A# --
SLS-24-120T 24 V @ 12.0 A# --
SLD12-1010-12T112 V @ 1 A
or 15 V @ .8 A
-12 V @ 1 A
or -15 V @ .8
-
SLD12-1818-12T112 V @ 1.8 A
or 15 V @ 1.5 A
-12 V @ 1.8 A
or -15 V @ 1.5 A
-
SLD-12-3434-12T12 V @ 3.4 A#-12 V @ 3.4 A#-
SLD-15-3030-15T15 V @ 3 A#-15 V @ 3 A#-
SLD-12-6034-05T 5 V @ 6 A*# 12 V @ 3.4 A#-
SLD-12-3015-05T5 V @ 3 A*# 12 V@ 1.5 A-
SLT12-20404-12T15 V @ 2 A*#12 V @ .4 A
or 15 V @ .4 A
-12 V @ .4 A
or -15 V @ .4 A
SLT12-31010-12T15 V @ 3 A*#12 V @ 1 A#
or 15 V @ .8 A
-12 V @ 1 A#
or -15 V @ .8 A
SLT12-61010-12T15V @ 6 A*#12 V @ 1 A
or 15 V @ 1 A
-12 V @ 1 A
or -15 V @ 1 A
SLT12-61818-12T1 5V @ 6A*#12 V @1.8 A
or 15 V @1.5 A
-12 V @ 1.8 A
or -15 V @ 1.5 A
SLT24-30530-05T15V @ 3A*-5 V @ .5 A*24 V @ 3 A*
Over Voltage Protector (OVP)
SLO-12-000-1

6.2 V to 34 V
Adjustable @ 8 V

For Cases B through K
SLO-12-000-TB

6.2 V to 34 V
Adjustable @ 8 V

For Case A or Cases B through K
(when used with a cover)