|
The Next Generation SDN "P" Series (Single and Three Phase Units, 60-960 Watts) |
DIN Rail power supplies in this industry just got better. By adding a “P” to the single phase part number, you get better performance, additional applications and Power Factor Correction. These next generation power supplies have industry leading performance with a true industrial grade design and high quality that meets difficult industrial environmental conditions including high shock, vibration, and wide temperature ranges over the long life cycle of industrial equipment. |
- Power Factor Correction
- Auto Select 115/230 VAC, 50/60 Hz Input
- Single Phase models meet SEMI F47 Sag Immunity
- Class 1, Div 2 Hazardous Locations
- Improved metal mounting clip
- DC OK Signal
- Adjustable Voltage
- Industrial grade design.
- 10oC to 60oC operation without derating. Indefinite short circuit, overvoltage and overtemperature protection. - Powers high inrush loads without shutdown or foldback.
- - Rugged metal case and DIN connector.
- SDN10-24-100P New Compact width (3.26”)
- Parallel Capability standard on all units.
- Broad range ( 2.5 A through 40 A) of product to fit almost any application.
- Narrow width on rail for space critical applications.
- 2.5-24-100P meets NEC Class 2.
|
| - User-friendly front panel.
- Large, rugged, accessible, multiple connection screw terminations. - Easy installation. - High MTBF and reliability
- Five year warranty.
- Single and three phase inputs available.
- Highly efficient >90% switching technology.
| EMC and Low Volt. Directive | UL 508 Listed IND CONT. EQ. 18 WM, E61379 | UL 60950 E137632 cUL/CSA-C2202 No. 234-M90 |
- Industrial/Machine control
| | | | | | | - Semiconductor Fabrication Equipment
| | |
- Chassis Mount Bracket (SDNPMBRK2)
Description | Catalog Number | SDN 2.5-24-100P | SDN 4-24-100P | SDN 5-24-100P | SDN 10-24-100P | SDN 20-24-100P | Input | Nominal Voltage | 115/230 VAC user select (no manual required) | -AC Range | 85-132/176-264 VAC | -DC Range | 90-375 VDC | 210 - 375 VDC | N/A | -Frequency | 47 - 63 Hz, 400 Hz Possible | Nominal Current1 | 1.3 A. / 0.7 A | 2.6 A. / 1.4 A | 6 A / 2.8 A typical | 12 A/6 A | -Inrush current max. | typ. <25 A | typ. <20 A | typ. <40 A | Efficiency (Losses2) | >87.5% typ (8.6 W) | >88% typ (13.1 W) | >88% typ (16.4 W) | >88% typ (32.7 W) | >90% typ (48 W) | Output | Nominal Voltage | 24 VDC (22.5 - 28.5 VDC Adj.) | -Tolerance | <±2% overall(combination line, load, time and temperature related changes) | -Ripple3 | < 50 mVpp | Nominal Current | 2.5 A (60 W) | 4 A (100 W) | 5 A (120 W) | 10 A (240 W) | 20 A (480 W) | -Peak Power4 | 2x Nominal Current < 2 sec. | 4.2 A max | 6 A 2x Nominal Current < 2 sec. | 12 A 2x Nominal Current < 2 sec. | 2x Nominal Current < 2 sec. | -Current Limit | Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current) | Holdup Time | > 20 ms (Full load, 100 VAC Input @ Tamb = +25oC to 95% output voltage. | Parallel Operation | Single or Parallel use is selectable via Front Panel Jumper. | General | EMI -Emissions | EN50081-1,-2 Class B EN55011, EN55022 Radiated and Conducted including Annex A. | -Immunity | EN50082-1, -2; EN61000-4-2 Level 4, EN61000-4-3 Level 3; EN61000-4-6 Level 3; EN61000-4-4 Level 4 input and Level 3 output; EN61000-4-5 Isolation Class 4 (SDN8-5-24 is Class 3), EN61000-4-11; Transient resistance according to VDE 0160/W2 over entire load range. | Approvals | EN60950; EN50178; EN60204; UL508 Listed, cULus; UL1950, cRUus, SDN2.5 - Class 2 LPS; CE (LVD 73/23 & 93/68/EWG, EMC 89/336 & 93/68/EWG; Transient Handling VDE 0160/W2. SDN 8-5-24 is CE marked with SE>V<42 V only. | Temperature | Storage: -25oC...+85oC Operation. -10o-60oC full power with operation to 70oC possible with a linear derating to half power from 60oC to 70oC. The relative humidity is 95% maximum non condensing. | Warranty | 5 years | General Protections/ Safety | Protected against short-circuit, overload, open-circuit. Overvoltage protection (OVP) for output set >30.5 but < 33 VDC, Auto Recovery. Protection class I (IEC536), degree of protection: IP20 (VDE 0470, IEC 529) Safe low voltage: SELV (acc. EN60950). | Status Indicators | Green LED and DC OK signal (300 mA @ 60 VDC) | Installation | Fusing | -Input | Internally fused. External 10 A slow acting fusing for the input is recommended for SDN2.5, 4 5 and 10P models. A 16A slow acting fuse or time-delay circuit breaker is recommended for the SDN20 model. | -Output | Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. | Mounting | Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK2 required). | Connections | Input: IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. 16-12 AWG (0.5-4 mm2) for flexible conductors. Output: Two connectors per output, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. | Case | Fully enclosed metal housing with fine ventilation grid to keep out small parts. | -Free Space | 25 mm above/below 25 mm left/right 10 mm in front | 25 mm above/below 25 mm left/right 15 mm in front | 70 mm above/below 25 mm left/right 15 mm in front | H x W x D (inches/mm) | 4.88 x 1.97 x 4.55 (124 x 50 x 116) | 4.88 x 2.56 x 4.55 (124 x 65 x 116) | 4.88 x 3.26 x 4.55 (124 x 83 x 116) | 4.88 x 6.88 x 4.55 (124 x 175 x 116) | Weight (lbs/g) | 1 lb (460g) | 1.5 lb (620g) | 2.2 lbs (1100g) | 3 lbs (1520g) | Notes: 1. Input current ratings are conservatively specified with low input, line conditions, worst case efficiency and power factor. 2. Losses are heat dissipation in watts at full load, nominal input line. 3. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor. 4. All peak power is calculated at 24 Volt levels. 5. SDN20-24-100 can be ordered until the SDN20-24-100P is available for shipment (September, 2003). |
Description | Catalog Number | SDN 5-24-480 | SDN 10-24-480 | SDN 20-24-480C | SDN 30-24-480 | SDN 40-24-480 | Input | Nominal Voltage | 3Æ 380-480 VAC Auto Range | 1Æ or 3Æ, 380 - 480 VAC1 | 3Æ 380-480 VAC | -AC Range | 340-576 VAC | -DC Range | 450 - 820 VDC | -Frequency | 47 - 65 Hz | Nominal Current2 | 0.5 A | 1 A | 1.5 A | 2.0 A | 3.0 A | -Inrush current | typ. < 18 A | typ. < 30 A | Efficiency (Losses2) | >90% typ (12 W) | >90% typ (48 W) | >90% typ (72 W) | >90% typ (96 W) | Power Factor Correction | Units fulfill EN61000-3-2 | Output | Nominal Voltage | 24-28 VDC Adj. (22.3 - 28.5 VDC adj.) | -Tolerance | <±2% overall (combination line. load, time and temperature related changes) | -Ripple4 | < 50 mVpp | Nominal Current | 5 A (120 W) | 10 A (240 W) | 20 A (480 W) | 30 A (720 W) | 40 A (960 W) | -Peak Current | 6 A 2x Nominal Current < 2 sec. | 12 A 2x Nominal Current < 2 sec. | 25 A 2x Nominal Current < 2 sec. | 35 A 1.5 x Nominal Current < 2 sec. | 45 A 2x Nominal Current < 2 sec. | -Current Limit | Fold Forward (Current rises, voltage drops to maintain constant power during overload up to max peak current) | Holdup Time | >20 ms | Parallel Operation | The SDN20/30 may be passively paralleled by selecting the "P" position of the jumper on the unit. The SDN40 contains active current balancing. | General | EMI -Emissions
-Immunity |
EN50081-1,-2 Class B EN55011, EN55022 Radiated and Conducted including Annex A. | EN50082-1, -2; EN61000-4-2 Level 4, EN61000-4-3 Level 3; EN61000-4-6 Level 3; EN61000-4-4 Level 4 input and Level 3 output; EN61000-4-5 Isolation Class 4, EN61000-4-11; Transient resistance according to VDE 0160/W2 over entire load range. | Approvals | CB Scheme, EN60950; EN50178; EN60204; UL508 Listed, cULus; UL60950, cRUus, CE (LVD 73/23 & 93/68/EEC). EN61000-3-2, IEC 60079-15 (Class 1, Zone 2 hazardous location, Groups IIA, IIB, IIC w/T3 temp class up to 60°C Ambient. | Temperature | Storage: -25oC...+85oC Operation. -10o-60oC full power with operation to 70oC possible with a linear derating to half power from 60oC to 70oC. (Convection cooling, no forced air required). Operation up to 50% load permissable with sideways or front side up mounting orientation. The relative humidity is less <90% RH, noncondensing; IEC 68-2-2, 68-2-3. | Warranty | 5 years | General Protection/ Safety | Protected against continuous short-circuit, overload, open-circuit. Protection class 1 (IEC536), degree of protection IP20 (IEC529). Safe low voltage: SELV (acc. EN60950). | Status Indicators | Green LED on, when Vout = 18V or greater. | Installation | Fusing | -Input | Internally fused. | -Output | Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. | Mounting | Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK2 required). | Connections | Input: IP20 related screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. 16-12 AWG (0.5-4 mm2) for flexible conductors. Output: two connectors per output, connector size range: 16-10 AWG (1.5 - 6 mm2) for solid connectors. | Case | Fully enclosed metal housing with fine ventilation grid to keep out small parts. | -Free Space | 25 mm above/below 25 mm left/right 15 mm in front | 70 mm above/below 25 mm left/right 15 mm in front | H x W x D (inches/mm) | 4.88 x 2.91 x 4.55 (124 x 73 x 116) | 4.88 x 3.5 x 4.55 (124 x 89 x 116) | 4.88 x 5.9 x 4.55 (124 x 150 x 116) | 4.88 x 9.72 x 4.55 (125 x 247 x 116) | 4.88 x 11.1 x 4.55 (125 x 282 x 116) | Weight (lbs/g) | 1.7 lbs (730g) | 2.16 lbs (980g) | 3.97 lbs (1800g) | 4 lbs (2000g) | 6.6 lbs (3300g) | Notes: 1. For the SDN20-24-480C, single phase input is permissible but output is derated to 75% (15 Amps @ 24 VDC). 2. Input current ratings are conservatively specified with low input, worst case efficiency values and power factor. 3. Losses are heat dissipation in watts at full load, nominal input line. 4. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor. |
|