• QUESTIONS? GIVE US A CALL! 1 (570) 823-6181

Navigate to the undefined homepage

You are here:Home >
SolaHD 63TCC375

Sola 63TCC375 3PH REG 75KVA 480D-480Y

SolaHD 63TCC375 - Image 1 of 0
SolaHD 63TCC375 - Image 2 of 0
SolaHD 63TCC375 - Image 1 of 0
SolaHD 63TCC375 - Image 2 of 0
SolaHD 63TCC375 - Image 1 of 0
SolaHD 63TCC375 - Image 2 of 0

SolaHD 63TCC375 3PH REG 75KVA 480D-480Y

SolaHD
List Price: $58,800.92
$
You save $!
SolaHD 63TCC375
  • Manufacturer:: SolaHD
Product Code: 63TCC375
UPC Code: 78347203051
SOLATRON™ Plus Series - Three Phase Power Conditioner

These three phase power conditioner units protect equipment from voltage sags and spikes, switching transients, lightning, and induced surges by a carefully designed surge suppression circuit linked to a shielded isolation transformer and input and output filters.

These power conditioner units hold output voltage regulation to a maximum of ±5%, even with an input voltage window of +15% to -25%. Response time to any line variation is 1.5 cycles regardless of power factor. The power conditioner units operate with 150 dB Common Mode noise attenuation and 65 dB Normal Mode noise attenuation at 100 kHz.

Features

  • Rugged, industrial design
  • High overload capability
  • High MTBF - No fans used
  • No power factor restriction on loads
  • Tight regulation of ±3% for protection against sag (-25%) and swell (+15%) conditions
  • Failsafe, no-break, auto-bypass
  • Status indicating lights
  • Shielded, copper wound isolation transformer
  • Surge suppression to ANSI/IEEE and IEC Standards
  • High efficiency (96%) microprocessor controlled tap switcher
  • Automatic under voltage protection
  • UL1012, UL1449-2, cULus Listed
Applications

  • Automatic Packaging Machinery
  • Data Rooms
  • UPS Bypass Circuits
  • Retail Store
  • Process Equipment

Related Products

  • STV100K Surge Suppressors
  • General Purpose Transformers

Specifications

Mechanical

Indicators Indicating Lamps: 2 amber (overtemperature and bypass mode)
1 green (regulated output present)
Connections Field wired, terminal blocks
Size and Weight See Selection Table
Safety Agency Approvals UL1012 and UL1449-2
cUL (Canadian Standard C22.2 No 125) Complies with Part 15 Subpart J of FCC rules for a Class A computing device

Environmental

Audible Noise Less than 50 dBA at 3 feet
Ambient Temperature 0° to 40°C Operating, 0° to 80°C Storage
Operating Altitude 10,000 feet without derating
Operating Humidity 95% relative (non-condensing)

Electrical

Power Ratings 20, 30, 50, 75 KVA, Three Phase
Nominal Voltages See Selection Table
Input Voltage Range -25% to +15% of nominal rated voltage.
Output Voltage Range Regulated to ± 5% of nominal voltage with
an input voltage range of –25% to +15%.
Response Time Responds to any line variation in <1.5 cycles typical.
Technology Enhance Voltage Regulation (EVR), Microprocessor controlled electronic tap switching. 6 taps switched at zero current crossing with no output
interruption.
Operating Frequency 57-63 Hz
Load Power Factor No Restriction
Insulation Resistance 100 megohms from winding to core measured at 500 VDC
Efficiency 96% typical
Overload Capability 1000% of rated load for 1 second,
200% of rated load for 1 minute.
EMI Less than 0.2 gauss at a distance of 3 ft.

Protection

Under Voltage Output voltage will switch to bypass mode when input is less than 50% of nominal. Regulated output voltage will be reestablished once input voltage is with specifications.
Short Circuit Protection Input circuit breaker
Over Temperature Protection Amber lamp indication of over temperature at approximately
180°C. Unit switches to by-pass mode until internal temperature is reduced to specified values.

Noise Suppression Performance

Common Mode Noise Attenuation 150 dB at 100 kHz
Normal Mode Noise Attenuation 65 dB at 100 kHz
Surge Suppression Tested to ANSI/IEEE standard C62.41 A&B
(IEEE 587 Cat A and B), 1000-4, 1000-5

Selection Table

Output
KVA
Catalog
Number
VAC
Input
Dimensions
H x W x D (in/cm)
Ship Weight
(lbs/kg)
208 VAC Input, 208Y/120 VAC Output, 60 Hz
2063TAA32020842 x 28 x 26 (1016 x 712 x 661)600/273
3063TAA33020842 x 28 x 26 (1016 x 712 x 661)750/341
5063TAA35020842 x 28 x 26 (1016 x 712 x 661)950/432
7563TAA37520842 x 28 x 26 (1016 x 712 x 661)1200/545
480 VAC Input, 208Y/120 VAC Output, 60 Hz
2063TCA32048042 x 28 x 26 (1016 x 712 x 661)600/273
3063TCA33048042 x 28 x 26 (1016 x 712 x 661)750/341
5063TCA35048042 x 28 x 26 (1016 x 712 x 661)950/432
7563TCA37548042 x 28 x 26 (1016 x 712 x 661)1200/545
480 VAC Input, 480Y/277 VAC Output, 60 Hz
2063TCC32048042 x 28 x 26 (1016 x 712 x 661)600/273
3063TCC33048042 x 28 x 26 (1016 x 712 x 661)750/341
5063TCC35048042 x 28 x 26 (1016 x 712 x 661)950/432
7563TCC37548042 x 28 x 26 (1016 x 712 x 661)1200/545
600 VAC Input, 208Y/120 VAC Output, 60 Hz
2063TDA32060042 x 28 x 26 (1016 x 712 x 661)600/273
3063TDA33060042 x 28 x 26 (1016 x 712 x 661)750/341
5063TDA35060042 x 28 x 26 (1016 x 712 x 661)950/432
7563TDA37560042 x 28 x 26 (1016 x 712 x 661)1200/545