Sola 23-13-030-2 30VA CVS VOLTAGE REGULATOR
The SolaHD 23130302 30VA CVS Voltage Regulator offers superior voltage regulation with ±1% accuracy, making it a reliable power conditioning solution for industrial applications. Using patented ferroresonant transformer technology, this power conditioner effectively mitigates power disturbances like sags, surges, and brownouts, ensuring a stable and clean sinusoidal waveform. Its robust design requires no maintenance and is built to last, with a typical mean time before failure of 25 years.
Voltage regulation of ±1%
Harmonic filtering for clean power
Surge suppression per ANSI/IEE C62.41
Acts as a step-up/step-down transformer
Galvanic isolation for superior circuit protection
Hardwired, maintenance-free design
The SolaHD CVS voltage regulator is the ideal choice for sensitive industrial equipment like PLCs, laboratory gear, sound systems, and broadcast equipment. Its dependable power conditioning ensures minimal downtime, protecting your equipment from power disturbances and extending its operational lifespan.
Specifications |
Parameter | Condition | Value |
Voltage | Continuous at full load (lower input voltage possible at lighter load) | +10% to -20% of nominal |
For temporary surge or sags | +20% to -35% of nominal | |
Current1 | at Full Load & 80% of nominal input voltage | Iin @ (VA / .87) / (Vin * 80%) |
Frequency | See the Operating Characteristics pdf for details. | 60 Hz |
Output | ||
Line Regulation | Vin >80% and <110% of nominal | ±1% |
Overload Protection | At Nominal Input Voltage | Current limited at 1.65 times rated current |
Output Harmonic Distortion | At Full Load within Input Range | 3% total RMS content |
Noise Attenuation | -Common Mode -Transverse Mode | 40 dB 40 dB |
Output Harmonic Distortion | 3% total RMS content at full load. | |
General | ||
Efficiency | at Full Load | Up to 92% |
Storage Temperature | Humidity < 95% non-condensing | -20o to 80oC |
Operating Temperature | Humidity < 95% non-condensing | -20o to 50oC |
Audible Noise | Full Resistive Noise | 32 dBA to 65 dBA |
Approvals | 60 Hz Models | UL1012; CSA2 |
Warranty | r | 10 + 2 Years |
1 - Consult user manual for fuse sizing. |
Selection Table |
VA | Catalog Number | Voltage Input | Voltage Output | Height (inch) | Width (inch) | Depth (inch) | Ship Weight (lbs) | Design Style | Elec Conn |
30 | 23-13-030-2 | 120 | 120 | 6 | 4 | 5 | 7 | 1 | J |
60 | 23-13-060-2 | 120 | 120 | 7 | 4 | 5 | 9 | 1 | J |
120 | 23-22-112-2 | 120, 240 | 120 | 8 | 4 | 5 | 13 | 1 | J |
250 | 23-23-125-8 | 120, 240, 480 | 120 | 11 | 6 | 8 | 29 | 1 | G |
500 | 23-23-150-8 | 120, 208, 240, 480 | 120, 240 | 13 | 9 | 7 | 42 | 1 | H |
1000 | 23-23-210-8 | 120, 208, 240, 480 | 120, 240 | 17 | 9 | 7 | 65 | 1 | H |
2000 | 23-23-220-8 | 120, 208, 240, 480 | 120, 240 | 18 | 13 | 10 | 111 | 1 | H |
3000 | 23-23-230-8 | 120, 208, 240, 480 | 120, 240 | 19 | 13 | 10 | 142 | 1 | H |
5000 | 23-23-250-8 | 120, 208, 240, 480 | 120, 240 | 28 | 13 | 10 | 222 | 1 | H |
7500* | 23-28-275-6 | 240, 480 | 120, 240 | 27 | 25 | 9 | 365 | 2 | J |
*This unit is not CSA Certified |