TRANSMISSION PERFORMANCE
- ANSI/TIA-568-C.2: category 6A (1-500 MHz) specifications
- ANSI/TIA-568-C.2: category 6 (1-250 MHz) specifications (100% tested)
WIRING SCHEME
- ANSI/TIA-568-C.2: T568A & T568B
- ISO/IEC 11801 2nd Ed.: 8-position conductor/pair assignment (1-2/3-6/4-5/7-8)
CORD CONSTRUCTION
- – 4 stranded 26-AWG copper pairs in thermoplastic insulation, High-Density Polyethylene outer jacket
- – high-impact clear polycarbonate 8p8c plugs
- – IP67-rated industrial-grade thermoplastic plug housings
- – thermoplastic boots
- – thermoplastic strain relief
PLUG
- Contacts: phosphor bronze, min 50 μin of gold plating over 100 μin of nickel in contact area
- Insulation resistance: min 500 MOhm @ 100 Vdc
- Dielectric withstanding voltage: 1,000 Vdc/ac peak contact to contact @ 60 Hz for 1 min
- Contact resistance: max 20 mOhm
- Current rating: see figure
- Assembly: FCC Part 68 Subpart F
- Housing: UL listed 94V-0 flame retardant polycarbonate
- Retention: 50 N (11 lbf) for 60±5 s
- Mating cycle life: min 750 cycles
- Tensile strength: ≥ 20 N per wire
INDUSTRIAL PLUG HOUSING
- – industrial-grade high-impact flame-retardant thermoplastic
- – UL 94V-0 rated
- – IP67 rated (complete protection against dust, protection against the effects of temporary immersion up to 1 m (3 ft))
CABLE
CONDUCTOR:
- Material bare copper
- Size 26 AWG stranded (7 x 34 AWG strands per conductor)
INSULATION:
Color coding:
- blue/white-blue
- orange/white-orange
- green/white-green
- brown/white-brown
SHEATH:
- Diameter: < 5.58 mm (0.22 ± 0.01 in)
- Color: Black
- Tensile strength: > 400 N (90 lbf)
- Min. bend radius: 25 mm (1 in) recommended
SHIELDS:
Overall sheild of 38 AWG tinned copper braid. Aluminized polyester foil shield
ENVIRONMENTAL CONDITIONS
- Storage: -40 °C – +70 °C (-40 °F – +158 °F)
- Operation: -40 °C – +75 °C (-40 °F – +167 °F)
- RH (operation): max non-condensing 93 %
COMPLIANCE
ANSI/TIA-568-C.2, IEC 60603-7, IEC 61156-6, IEC 60332-1-2, FCC Part 68 Subpart F, UL 94V-0, RoSH
APPLICATIONS
X.21, V.11, S0, ISDN, CSMA/CD 10BASE-T, 100BASE-TX, 100BASE-T4, 100BASE-T2, 1000BASE-T, 10GBASE-T (up to 55 m (180 ft)), TR 4/16/100, 100BASE-VG, ATM LAN 25/51/155, TP-PMD
WARRANTY
- 5-year limited component warranty
- 10-year Signamax Link/Channel Warranty
- 15-year Signamax Extended Component Warranty
- 25-year Signamax Cabling System Warranty