M4 - CHARACTERISTICS |
Electrical Rating | - 5A 125 or 250V AC
- 3A 30V DC
- 0.4A 125V DC
|
Operating speed | |
Operating frequency | - Mechanically: 120 operations/min.
- Electrically: 30 operations/min.
|
Insulation resistance | |
Dielectric strength | - Between non-continuous terminals: 1000V AC 50/60 Hz, 1 minute
- Between each terminal and non-current carrying metal part and
- Between each terminal and ground: 1500V AC 50/60 Hz, 1 minute
|
Vibration | - Malfunction durability: 10 to 50Hz 1.5mm double amplitude
|
Shock | - Mechanical durability: Approx 1,000m/sec (approx 100G's)
- Malfunction durability: Approx. 300m/sec (approx 30G's)
|
Operating Temp | - -10º to +70º C (Without freezing)
|
Humidity | |
Service life | - Mechanically: 10,000,000 operations min
- Electrically: 200,000 operations min.
|
Protection Degree | |