Presentation | Highly efficient, easy-to-deploy 40kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. This UPS is for up to 4 smart modular high capacity battery strings, but is supplied without batteries, so you can easily customize the battery runtime. Includes 5x8 start-up service. |
---|---|
Lead time | Usually Ships within 2 Weeks |
Main Input Voltage | 400 V 3 phase |
---|---|
Other Input Voltage | 380 V 415 V |
Main Output Voltage | 400 V 3 phase |
Other Output Voltage | 380 V 415 V |
Kw Rating | 40 kW |
Rated power in VA | 40 kVA |
battery type | Internal modular battery VRLA |
Provided equipment | Dust filter Installation manual Integrated network management Start-Up Service EcoStruxure Ready |
battery voltage | 480V |
---|---|
End of Discharge Battery Voltage | 384 V |
End of Discharge Maximum Battery Current | 109 A |
Battery power in VAH | 0 VAh runtime |
Extendable Run Time | 0 |
Redundant | No |
---|
color | White |
---|---|
Height | 58.46 in (148.5 cm) |
Width | 20.51 in (52.1 cm) |
Depth | 33.35 in (84.7 cm) |
Net Weight | 440.92 lb(US) (200 kg) |
USB compatible | No |
Input Frequency | 40 - 70 Hz |
---|---|
Efficiency at full load | 340...460 V 400 V |
Maximum Input Current per Phase | 72 A |
Maximum Short Circuit Withstand (Icw) | 65 kA |
Input Total Harmonic Distortion | Less than 3% for full load |
Load power factor | From 0.7 leading to 0.7 lagging without any derating |
Input Power Factor at Full Load | 0.99 |
Max Configurable Power (Watts) | 40 kW |
---|---|
Harmonic distortion | Less than 3% |
Output Frequency (sync to mains) | 50 Hz sync to mains 60 Hz sync to mains |
Crest factor | 2.5 |
Waveform Type | Sine wave |
Output voltage tolerance | +/- 5% after 2ms +/-1% after 50ms |
Output Voltage THD | < 1% linear load and < 3% non-linear load |
Overload Operation | 10 minutes @ 125% and 60 seconds @ 150% |
bypass type | Built-in Static Bypass |
Maximum configurable power in VA | 40 kVA |
Standards | IEC 62040-1-1 IEC 62040-2 OSHPD |
---|
Ambient air temperature for operation | 32…104 °F (0…40 °C) |
---|---|
Relative Humidity | 0…95 % non-condensing |
Operating altitude | 0...3300 ft |
Ambient Air Temperature for Storage | 5…104 °F (-15…40 °C) |
Storage Relative Humidity | 10…80 % non-condensing |
Storage altitude | 0…10000 ft (0.00…3048.00 m) |
Acoustic level | 61 dBA |
Heat dissipation | 4658 Btu/h |
IP degree of protection | IP20 |
control panel | Touch Screen LCD User Interface |
---|
GTIN | 731304410065 |
---|
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 66.14 in (168 cm) |
Package 1 Width | 38.98 in (99 cm) |
Package 1 Length | 25.20 in (64 cm) |
Package 1 Weight | 440.92 lb(US) (200 kg) |
Warranty | 1 year on-site repair or replace with factory authorized Start-Up |
---|