APC GVSUPS20KRHS Galaxy VS UPS 20kW 400V with N+1 power module for external batteries, StaRT-up 5x8

APC
List Price: $40,560.00
$
You save $!
  • Manufacturer:: APC
Product Code: GVSUPS20KRHS
Overview
PresentationHighly efficient, easy-to-deploy 20kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5x8 start-up service and one additional power module for N+1 redundancy.
Lead timeUsually Ships within 2 Weeks
Main
Main Input Voltage400 V 3 phase
Other Input Voltage380 V
415 V
Main Output Voltage400 V 3 phase
Other Output Voltage380 V
415 V
Kw Rating20 kW
Rated power in VA20 kVA
battery typeExternal battery system
Li-Ion (Lithium Ion)
VRLA
Provided equipmentDust filter
EcoStruxure IT ready (UPS)
Installation guide
Integrated network management
Power modules ship installed
Start-Up Service
Batteries & Runtime
battery voltage384-576VDC
End of Discharge Battery Voltage307 V DC
End of Discharge Maximum Battery Current68 A
General
Bypass Voltage Tolerance+/- 10 %
RedundantYes
Physical
colorWhite
Height58.46 in (148.5 cm)
Width20.51 in (52.1 cm)
Depth33.35 in (84.7 cm)
Net Weight551.16 lb(US) (250 kg)
Input
Input Frequency40 - 70 Hz
Efficiency at full load340...460 V 400 V
Maximum Input Current per Phase30 A
Maximum Short Circuit Withstand (Icw)65 kA
Input Total Harmonic DistortionLess than 5% for full load
Load power factorFrom 0.7 leading to 0.7 lagging without any derating
Output
Max Configurable Power (Watts)20 kW
Output Frequency (sync to mains)50 Hz sync to mains
60 Hz sync to mains
50 Hz +/- 0.1 % for 50 Hz nominal not synced
60 Hz +/- 0.1 % for 60 Hz nominal not synced
Crest factor2.5
Waveform TypeSine wave
Output voltage tolerance+/-1% after 50ms
Output Voltage THD< 1% linear load and < 5% non-linear load
Overload Operation10 minutes @ 125% and 60 seconds @ 150%
bypass typeBuilt-in Static Bypass
Maximum configurable power in VA20 kVA
Conformance
StandardsEN/IEC 62040-1
EN/IEC 62040-2
FCC Part 15 class A
IEC 60721-4-2 Level 2M2
UL 1778 5th edition
Environmental
Ambient air temperature for operation32…104 °F (0…40 °C)
Relative Humidity0…95 % non-condensing
Operating altitude0...3300 ft
Ambient Air Temperature for Storage-13…131 °F (-25…55 °C)
Storage Relative Humidity10…80 % non-condensing
Acoustic level68 dBA
Heat dissipation2170 Btu/h
IP degree of protectionIP21
Communications & Management
control panelTouch Screen LCD User Interface
Ordering and shipping details
GTIN731304418269
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height66.14 in (168 cm)
Package 1 Width38.98 in (99 cm)
Package 1 Length25.20 in (64 cm)
Package 1 Weight551.16 lb(US) (250 kg)
Contractual warranty
Warranty1 year on-site repair or replace with factory authorized Start-Up