Presentation | Highly efficient, easy-to-deploy 20kW, 480V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5x8 start-up service and one additional power module for N+1 redundancy. |
---|---|
Lead time | Usually Ships within 2 Weeks |
Main Input Voltage | 480 V 3 phase |
---|---|
Main Output Voltage | 480 V 3 phase |
Kw Rating | 20 kW |
Rated power in VA | 20 kVA |
battery type | External battery system Li-Ion (Lithium Ion) VRLA |
Provided equipment | Dust filter EcoStruxure IT ready (UPS) Installation guide Integrated network management Power modules ship installed Start-Up Service |
battery voltage | 384-576VDC |
---|---|
End of Discharge Battery Voltage | 307 V DC |
End of Discharge Maximum Battery Current | 68 A |
Bypass Voltage Tolerance | +/- 10 % |
---|---|
Redundant | Yes |
color | White |
---|---|
Height | 58.46 in (148.5 cm) |
Width | 20.51 in (52.1 cm) |
Depth | 33.35 in (84.7 cm) |
Net Weight | 551.16 lb(US) (250 kg) |
Input Frequency | 40 - 70 Hz |
---|---|
Efficiency at full load | 408...552 V 480 V |
Maximum Input Current per Phase | 30 A |
Maximum Short Circuit Withstand (Icw) | 65 kA |
Input Total Harmonic Distortion | Less than 5% for full load |
Load power factor | From 0.7 leading to 0.7 lagging without any derating |
Max Configurable Power (Watts) | 20 kW |
---|---|
Output Frequency (sync to mains) | 50 Hz sync to mains 60 Hz sync to mains 50 Hz +/- 0.1 % for 50 Hz nominal not synced 60 Hz +/- 0.1 % for 60 Hz nominal not synced |
Crest factor | 2.5 |
Waveform Type | Sine wave |
Output voltage tolerance | +/-1% after 50ms |
Output Voltage THD | < 1% linear load and < 5% non-linear load |
Overload Operation | 10 minutes @ 125% and 60 seconds @ 150% |
bypass type | Built-in Static Bypass |
Maximum configurable power in VA | 20 kVA |
Standards | IEC 62040-1-1 IEC 62040-2 UL 1778 5th edition FCC Part 15 class A IEC 60721-4-2 Level 2M2 UL 924 Listed |
---|
Ambient air temperature for operation | 32…104 °F (0…40 °C) |
---|---|
Relative Humidity | 0…95 % non-condensing |
Operating altitude | 0...3300 ft |
Ambient Air Temperature for Storage | -13…131 °F (-25…55 °C) |
Storage Relative Humidity | 10…80 % non-condensing |
Acoustic level | 64 dBA |
Heat dissipation | 2188 Btu/h |
IP degree of protection | IP21 |
control panel | Touch Screen LCD User Interface |
---|
GTIN | 731304418474 |
---|
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Warranty | 1 year on-site repair or replace with factory authorized Start-Up |
---|